Evaluation of 1.5mm Lead Shield for Radiological Protection and Comparison of Calculated and Measured Results of Equivalent Dose

Evaluation of radiation protective devices in radiology departments is one of the practices that ensure radiation protection and staff and patients safety in hospitals. A research work to evaluate 1.5mm lead shield used for radiological protection was carried out in Radiological Unit of Sharda  Hos...

Full description

Saved in:
Bibliographic Details
Main Authors: M. Alhassan, B. Khan, J.T. Baraya
Format: Article
Language:English
Published: Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP) 2020-01-01
Series:Journal of Applied Sciences and Environmental Management
Subjects:
Online Access:https://www.Ajol.Info/index.php/jasem/article/view/192535
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823864664258248704
author M. Alhassan
B. Khan
J.T. Baraya
author_facet M. Alhassan
B. Khan
J.T. Baraya
author_sort M. Alhassan
collection DOAJ
description Evaluation of radiation protective devices in radiology departments is one of the practices that ensure radiation protection and staff and patients safety in hospitals. A research work to evaluate 1.5mm lead shield used for radiological protection was carried out in Radiological Unit of Sharda  Hospital, of Sharda University, India, using 300mA fixed x-ray machine room. The evaluation was done in the x-ray energy (kVp) range between 52- 81 and by using calculative procedure and by direct measurement of the radiation dose rates. The two results were compared. The results shows that, in the absence of the shield, only 11.82% of the radiation exposure was attenuated by the air space before reaching the  radiographer’s stand, while in the presence of the shield, 96.50% was attenuated, whereas, for the measured result only 10.17% was attenuated in the absence of the shield and 89.83% was attenuated in the presence of the shield before reaching the radiographer’s stand. The unit of radiation exposure was converted to that of equivalent dose and that of effective dose in order to assess the radiographer’s safety level behind the shield. It was found that, the equivalent/effective dose is as low as to be accepted according to the policy of ALARA (As Low As Reasonably Achievable), and within the NCRP recommended limit. This guaranteed the effectiveness of the lead shield of 1.5mm thickness in the x-ray energy range used in this study. Keywords: Lead shield, radiological protection, effectiveness of 1.5mm leadshield, presence of shield, absence of shield, radiographer’s safety.  
format Article
id doaj-art-22ea0fcb8d2e4b8fac6b27a14e11c9a5
institution Kabale University
issn 2659-1502
2659-1499
language English
publishDate 2020-01-01
publisher Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP)
record_format Article
series Journal of Applied Sciences and Environmental Management
spelling doaj-art-22ea0fcb8d2e4b8fac6b27a14e11c9a52025-02-08T19:51:24ZengJoint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP)Journal of Applied Sciences and Environmental Management2659-15022659-14992020-01-012312Evaluation of 1.5mm Lead Shield for Radiological Protection and Comparison of Calculated and Measured Results of Equivalent DoseM. AlhassanB. KhanJ.T. Baraya Evaluation of radiation protective devices in radiology departments is one of the practices that ensure radiation protection and staff and patients safety in hospitals. A research work to evaluate 1.5mm lead shield used for radiological protection was carried out in Radiological Unit of Sharda  Hospital, of Sharda University, India, using 300mA fixed x-ray machine room. The evaluation was done in the x-ray energy (kVp) range between 52- 81 and by using calculative procedure and by direct measurement of the radiation dose rates. The two results were compared. The results shows that, in the absence of the shield, only 11.82% of the radiation exposure was attenuated by the air space before reaching the  radiographer’s stand, while in the presence of the shield, 96.50% was attenuated, whereas, for the measured result only 10.17% was attenuated in the absence of the shield and 89.83% was attenuated in the presence of the shield before reaching the radiographer’s stand. The unit of radiation exposure was converted to that of equivalent dose and that of effective dose in order to assess the radiographer’s safety level behind the shield. It was found that, the equivalent/effective dose is as low as to be accepted according to the policy of ALARA (As Low As Reasonably Achievable), and within the NCRP recommended limit. This guaranteed the effectiveness of the lead shield of 1.5mm thickness in the x-ray energy range used in this study. Keywords: Lead shield, radiological protection, effectiveness of 1.5mm leadshield, presence of shield, absence of shield, radiographer’s safety.   https://www.Ajol.Info/index.php/jasem/article/view/192535Lead shieldradiological protectioneffectiveness of 1.5mm leadshieldpresence of shieldabsence of shieldradiographer’s safety.
spellingShingle M. Alhassan
B. Khan
J.T. Baraya
Evaluation of 1.5mm Lead Shield for Radiological Protection and Comparison of Calculated and Measured Results of Equivalent Dose
Journal of Applied Sciences and Environmental Management
Lead shield
radiological protection
effectiveness of 1.5mm leadshield
presence of shield
absence of shield
radiographer’s safety.
title Evaluation of 1.5mm Lead Shield for Radiological Protection and Comparison of Calculated and Measured Results of Equivalent Dose
title_full Evaluation of 1.5mm Lead Shield for Radiological Protection and Comparison of Calculated and Measured Results of Equivalent Dose
title_fullStr Evaluation of 1.5mm Lead Shield for Radiological Protection and Comparison of Calculated and Measured Results of Equivalent Dose
title_full_unstemmed Evaluation of 1.5mm Lead Shield for Radiological Protection and Comparison of Calculated and Measured Results of Equivalent Dose
title_short Evaluation of 1.5mm Lead Shield for Radiological Protection and Comparison of Calculated and Measured Results of Equivalent Dose
title_sort evaluation of 1 5mm lead shield for radiological protection and comparison of calculated and measured results of equivalent dose
topic Lead shield
radiological protection
effectiveness of 1.5mm leadshield
presence of shield
absence of shield
radiographer’s safety.
url https://www.Ajol.Info/index.php/jasem/article/view/192535
work_keys_str_mv AT malhassan evaluationof15mmleadshieldforradiologicalprotectionandcomparisonofcalculatedandmeasuredresultsofequivalentdose
AT bkhan evaluationof15mmleadshieldforradiologicalprotectionandcomparisonofcalculatedandmeasuredresultsofequivalentdose
AT jtbaraya evaluationof15mmleadshieldforradiologicalprotectionandcomparisonofcalculatedandmeasuredresultsofequivalentdose