Method of regulating power quality indicators

One of the important requirements for electricity supply is ensuring the quality of electricity, which is understood as the degree of compliance of quality indicators with accepted standards. Deviation of voltage and other quality indicators from established norms significantly affects the operatio...

Full description

Saved in:
Bibliographic Details
Main Author: Anton Panov
Format: Article
Language:English
Published: Oles Honchar Dnipro National University 2023-06-01
Series:Challenges and Issues of Modern Science
Online Access:https://cims.fti.dp.ua/j/article/view/19
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823858767414951936
author Anton Panov
author_facet Anton Panov
author_sort Anton Panov
collection DOAJ
description One of the important requirements for electricity supply is ensuring the quality of electricity, which is understood as the degree of compliance of quality indicators with accepted standards. Deviation of voltage and other quality indicators from established norms significantly affects the operation of electrified equipment and electrical networks, which leads to electromagnetic and technological components of economic damage. Also, voltage asymmetry is one of the urgent problems of 0.4 kV three-phase electrical networks. The asymmetry of the voltage is manifested in the inequality between the models of the phase voltage vectors and the shift angles between them. IEEE Std 1100-2005. IEEE Recommended Practice for Powering and Grounding Electronic Equipment [1] (hereinafter IEEE) and DSTU EN 50160:2014 "Characteristics of power supply voltage in electrical networks of general purpose" (hereinafter DSTU) [2] establish indicators and norms of power quality in electrical networks of power supply systems general purpose alternating three-phase and single-phase current with a frequency of 50 Hz at the points to which electric networks owned by different consumers of electric energy or receivers of electric energy (points of general connection) are connected. The power quality standards established by the standard are electromagnetic compatibility levels for conductive electromagnetic disturbances in general purpose power supply systems. In compliance with established standards of electricity quality, electromagnetic compatibility of electrical networks of energy supply organizations and electrical networks of electricity consumers is ensured.
format Article
id doaj-art-54fd151997d14f8894c6e4ffa3862759
institution Kabale University
issn 3083-5704
language English
publishDate 2023-06-01
publisher Oles Honchar Dnipro National University
record_format Article
series Challenges and Issues of Modern Science
spelling doaj-art-54fd151997d14f8894c6e4ffa38627592025-02-11T09:58:23ZengOles Honchar Dnipro National UniversityChallenges and Issues of Modern Science3083-57042023-06-011Method of regulating power quality indicatorsAnton Panov0https://orcid.org/0000-0002-0688-1430State Biotechnological University One of the important requirements for electricity supply is ensuring the quality of electricity, which is understood as the degree of compliance of quality indicators with accepted standards. Deviation of voltage and other quality indicators from established norms significantly affects the operation of electrified equipment and electrical networks, which leads to electromagnetic and technological components of economic damage. Also, voltage asymmetry is one of the urgent problems of 0.4 kV three-phase electrical networks. The asymmetry of the voltage is manifested in the inequality between the models of the phase voltage vectors and the shift angles between them. IEEE Std 1100-2005. IEEE Recommended Practice for Powering and Grounding Electronic Equipment [1] (hereinafter IEEE) and DSTU EN 50160:2014 "Characteristics of power supply voltage in electrical networks of general purpose" (hereinafter DSTU) [2] establish indicators and norms of power quality in electrical networks of power supply systems general purpose alternating three-phase and single-phase current with a frequency of 50 Hz at the points to which electric networks owned by different consumers of electric energy or receivers of electric energy (points of general connection) are connected. The power quality standards established by the standard are electromagnetic compatibility levels for conductive electromagnetic disturbances in general purpose power supply systems. In compliance with established standards of electricity quality, electromagnetic compatibility of electrical networks of energy supply organizations and electrical networks of electricity consumers is ensured. https://cims.fti.dp.ua/j/article/view/19
spellingShingle Anton Panov
Method of regulating power quality indicators
Challenges and Issues of Modern Science
title Method of regulating power quality indicators
title_full Method of regulating power quality indicators
title_fullStr Method of regulating power quality indicators
title_full_unstemmed Method of regulating power quality indicators
title_short Method of regulating power quality indicators
title_sort method of regulating power quality indicators
url https://cims.fti.dp.ua/j/article/view/19
work_keys_str_mv AT antonpanov methodofregulatingpowerqualityindicators