A GA-BP neural network algorithm for fault detection of transmission tower bolts

BackgroundIn the power system, the identification of the health status of the transmission tower is a daily task that must be performed. In addition, bolt loosening is a common damage mode affecting the main materials of transmission towers. When bolt loosening occurs, it weakens the bearing capacit...

Full description

Saved in:
Bibliographic Details
Main Authors: Ziqiang Lu, Pengjie He, Huiwei Liu, Jie Li, Ziying Lu
Format: Article
Language:English
Published: Frontiers Media S.A. 2025-02-01
Series:Frontiers in Mechanical Engineering
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fmech.2024.1496377/full
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:BackgroundIn the power system, the identification of the health status of the transmission tower is a daily task that must be performed. In addition, bolt loosening is a common damage mode affecting the main materials of transmission towers. When bolt loosening occurs, it weakens the bearing capacity of the transmission tower. If not detected and addressed in a timely manner, serious adverse events, such as tower collapse, may occur which will endanger the normal operation of the power system.MethodsBased on this, in order to ensure the normal operation of the transmission tower and improve the identification effect of bolt loosening, the GP-BP neural network algorithm was applied to the detection process. The feasibility of this algorithm was evaluated through the quantitative analysis of different damage degrees.ResultThe results are as follows: 1) except for the average accuracy rate of substructure 7, which is 89.74%, the identification accuracy of other substructures is more than 90%, indicating that the GA-BP neural network algorithm is effective in identifying the single-damage degree of the tower bolt loosening in the main material; 2) the identification accuracy of double-damage substructure is also more than 90%, indicating that the GA-BP algorithm is effective in identifying the double-damage degree of the tower bolt loosening in the main material.ConclusionIn summary, it can be concluded that both the single- and double-damage degree conditions exhibit a relatively considerable recognition accuracy. In addition, the recognition effect of the algorithm under the double-damage degree condition is better than that of the single-damage degree condition. Therefore, it can be applied in practical projects involving double-damage degree conditions to improve the recognition effect of bolt-loosening faults and provide reliable technical support for the safe operation of transmission equipment.
ISSN:2297-3079