Cost-Benefit analysis for energy efficiency of existing hotel building

The purpose of establishing a hotel building itself is expected to get good financial benefits as much as possible. In order to increase the cost-benefit for the building, increasing the energy efficiency is a major way to save energy and thus reduce energy expenses from the existing building. This...

Full description

Saved in:
Bibliographic Details
Main Authors: Satriopratomo Dhimas F., Padma Devia Yatnanta, Susanti Lilya
Format: Article
Language:English
Published: EDP Sciences 2025-01-01
Series:BIO Web of Conferences
Online Access:https://www.bio-conferences.org/articles/bioconf/pdf/2025/10/bioconf_safe24_02001.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1825206569500934144
author Satriopratomo Dhimas F.
Padma Devia Yatnanta
Susanti Lilya
author_facet Satriopratomo Dhimas F.
Padma Devia Yatnanta
Susanti Lilya
author_sort Satriopratomo Dhimas F.
collection DOAJ
description The purpose of establishing a hotel building itself is expected to get good financial benefits as much as possible. In order to increase the cost-benefit for the building, increasing the energy efficiency is a major way to save energy and thus reduce energy expenses from the existing building. This research aim is to analyze energy consumption and cost-benefit at repaired existing hotel building. The method that used in this research are existing building modeling, energy and cost simulation, provide repairmen alternatives to reduce energy consumption and cost, and determine the optimum alternative design. The simulation using Sefaira as a Sketchup Software plug-in. In this research, the object is hotel building that have 11 floor and 1 basement at Yogyakarta, Indonesia. The result show that the existing hotel building consume 977 kWh/m2/year and energy cost IDR 2.994.403.821. The alternative for repairmen existing hotel building area the replacement of tint window, insulated wall application, skylight addition, and window addition at dismantle room area. For the selected alternative is the hybrid of window addition at dismantled room area and insulated wall that decrease energy consumption and cost into 871,06 kWh/m2/year (12,16%) and IDR 2.346.637.473 respectively. It means the energy cost savings is IDR 272.042.266 (9,09%). Furthermore, from cost-benefit analysis resulted the economic internal rate of return (EIRR) 13,61%, payback period in 5,52 years. In 20 years, PV Cost IDR 14.493.532.315,84 and PV benefit IDR 16.422.494.153,10, resulted the NPV at IDR 1.928.961.837,26 and BCR value 1.13.
format Article
id doaj-art-7238a00a237344afa20d2b1ec1fb2a8d
institution Kabale University
issn 2117-4458
language English
publishDate 2025-01-01
publisher EDP Sciences
record_format Article
series BIO Web of Conferences
spelling doaj-art-7238a00a237344afa20d2b1ec1fb2a8d2025-02-07T08:20:35ZengEDP SciencesBIO Web of Conferences2117-44582025-01-011590200110.1051/bioconf/202515902001bioconf_safe24_02001Cost-Benefit analysis for energy efficiency of existing hotel buildingSatriopratomo Dhimas F.0Padma Devia Yatnanta1Susanti Lilya2Magister Program of Civil Engineering, Brawijaya UniversityDepartment of Civil Engineering, Brawijaya UniversityMagister Program of Civil Engineering, Brawijaya UniversityThe purpose of establishing a hotel building itself is expected to get good financial benefits as much as possible. In order to increase the cost-benefit for the building, increasing the energy efficiency is a major way to save energy and thus reduce energy expenses from the existing building. This research aim is to analyze energy consumption and cost-benefit at repaired existing hotel building. The method that used in this research are existing building modeling, energy and cost simulation, provide repairmen alternatives to reduce energy consumption and cost, and determine the optimum alternative design. The simulation using Sefaira as a Sketchup Software plug-in. In this research, the object is hotel building that have 11 floor and 1 basement at Yogyakarta, Indonesia. The result show that the existing hotel building consume 977 kWh/m2/year and energy cost IDR 2.994.403.821. The alternative for repairmen existing hotel building area the replacement of tint window, insulated wall application, skylight addition, and window addition at dismantle room area. For the selected alternative is the hybrid of window addition at dismantled room area and insulated wall that decrease energy consumption and cost into 871,06 kWh/m2/year (12,16%) and IDR 2.346.637.473 respectively. It means the energy cost savings is IDR 272.042.266 (9,09%). Furthermore, from cost-benefit analysis resulted the economic internal rate of return (EIRR) 13,61%, payback period in 5,52 years. In 20 years, PV Cost IDR 14.493.532.315,84 and PV benefit IDR 16.422.494.153,10, resulted the NPV at IDR 1.928.961.837,26 and BCR value 1.13.https://www.bio-conferences.org/articles/bioconf/pdf/2025/10/bioconf_safe24_02001.pdf
spellingShingle Satriopratomo Dhimas F.
Padma Devia Yatnanta
Susanti Lilya
Cost-Benefit analysis for energy efficiency of existing hotel building
BIO Web of Conferences
title Cost-Benefit analysis for energy efficiency of existing hotel building
title_full Cost-Benefit analysis for energy efficiency of existing hotel building
title_fullStr Cost-Benefit analysis for energy efficiency of existing hotel building
title_full_unstemmed Cost-Benefit analysis for energy efficiency of existing hotel building
title_short Cost-Benefit analysis for energy efficiency of existing hotel building
title_sort cost benefit analysis for energy efficiency of existing hotel building
url https://www.bio-conferences.org/articles/bioconf/pdf/2025/10/bioconf_safe24_02001.pdf
work_keys_str_mv AT satriopratomodhimasf costbenefitanalysisforenergyefficiencyofexistinghotelbuilding
AT padmadeviayatnanta costbenefitanalysisforenergyefficiencyofexistinghotelbuilding
AT susantililya costbenefitanalysisforenergyefficiencyofexistinghotelbuilding