Portable humidifier for refrigeration systems isolation room in a simple residential house

Humans need fresh and clean air to live healthily. However, being in a dense and dense residential environment can potentially transmit diseases such as infections, bacteria, viruses, airborne microorganisms (airborne microorganisms), fungi, and other sources of infectious diseases. This is a concer...

Full description

Saved in:
Bibliographic Details
Main Authors: Ruhyat N., Firdaus A.
Format: Article
Language:English
Published: EDP Sciences 2025-01-01
Series:BIO Web of Conferences
Online Access:https://www.bio-conferences.org/articles/bioconf/pdf/2025/10/bioconf_safe24_06003.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1825206569778806784
author Ruhyat N.
Firdaus A.
author_facet Ruhyat N.
Firdaus A.
author_sort Ruhyat N.
collection DOAJ
description Humans need fresh and clean air to live healthily. However, being in a dense and dense residential environment can potentially transmit diseases such as infections, bacteria, viruses, airborne microorganisms (airborne microorganisms), fungi, and other sources of infectious diseases. This is a concern in the air conditioning system. The air conditioning system regulates the air conditioning in the room to meet ideal conditions such as temperature and humidity. If you look at the Technical Guidelines for Buildings and Infrastructure Standards for Emerging Infectious Diseases (PIE) Isolation Rooms from the Ministry of Health of the Republic of Indonesia in 2020, at least the air temperature of residential rooms can reach an air temperature of 24 ± 20°C, with a relative humidity of 60%, so that fresh air is fulfilled. Experiments on portable humidifiers using single and double condensers from a refrigeration system provide design data on the need for air temperature and humidity for isolation rooms in simple residential houses. The standard temperature can be reached in a portable humidifier with a single condenser, namely 26-28°C. However, the humidity is still relatively high, at 80%, so bacteria can survive. However, when the air temperature in the lowest section (evaporator) is conditioned (10, 15, and 20°C), the air temperature exceeds the standard limit (39,38°C), even though the humidity is very low, reaching 34%. In experiments using a double condenser, the standard temperature and humidity can be said to be achieved; the temperature is 31°C, and the humidity is at 67%.
format Article
id doaj-art-759cee4782ed47ef86a0fbebc659639b
institution Kabale University
issn 2117-4458
language English
publishDate 2025-01-01
publisher EDP Sciences
record_format Article
series BIO Web of Conferences
spelling doaj-art-759cee4782ed47ef86a0fbebc659639b2025-02-07T08:20:35ZengEDP SciencesBIO Web of Conferences2117-44582025-01-011590600310.1051/bioconf/202515906003bioconf_safe24_06003Portable humidifier for refrigeration systems isolation room in a simple residential houseRuhyat N.0Firdaus A.1Mechanical Engineering Department, Mercu Buana UniversityIndustrial Engineering Department, Mercu Buana UniversityHumans need fresh and clean air to live healthily. However, being in a dense and dense residential environment can potentially transmit diseases such as infections, bacteria, viruses, airborne microorganisms (airborne microorganisms), fungi, and other sources of infectious diseases. This is a concern in the air conditioning system. The air conditioning system regulates the air conditioning in the room to meet ideal conditions such as temperature and humidity. If you look at the Technical Guidelines for Buildings and Infrastructure Standards for Emerging Infectious Diseases (PIE) Isolation Rooms from the Ministry of Health of the Republic of Indonesia in 2020, at least the air temperature of residential rooms can reach an air temperature of 24 ± 20°C, with a relative humidity of 60%, so that fresh air is fulfilled. Experiments on portable humidifiers using single and double condensers from a refrigeration system provide design data on the need for air temperature and humidity for isolation rooms in simple residential houses. The standard temperature can be reached in a portable humidifier with a single condenser, namely 26-28°C. However, the humidity is still relatively high, at 80%, so bacteria can survive. However, when the air temperature in the lowest section (evaporator) is conditioned (10, 15, and 20°C), the air temperature exceeds the standard limit (39,38°C), even though the humidity is very low, reaching 34%. In experiments using a double condenser, the standard temperature and humidity can be said to be achieved; the temperature is 31°C, and the humidity is at 67%.https://www.bio-conferences.org/articles/bioconf/pdf/2025/10/bioconf_safe24_06003.pdf
spellingShingle Ruhyat N.
Firdaus A.
Portable humidifier for refrigeration systems isolation room in a simple residential house
BIO Web of Conferences
title Portable humidifier for refrigeration systems isolation room in a simple residential house
title_full Portable humidifier for refrigeration systems isolation room in a simple residential house
title_fullStr Portable humidifier for refrigeration systems isolation room in a simple residential house
title_full_unstemmed Portable humidifier for refrigeration systems isolation room in a simple residential house
title_short Portable humidifier for refrigeration systems isolation room in a simple residential house
title_sort portable humidifier for refrigeration systems isolation room in a simple residential house
url https://www.bio-conferences.org/articles/bioconf/pdf/2025/10/bioconf_safe24_06003.pdf
work_keys_str_mv AT ruhyatn portablehumidifierforrefrigerationsystemsisolationroominasimpleresidentialhouse
AT firdausa portablehumidifierforrefrigerationsystemsisolationroominasimpleresidentialhouse