Adaptive Neuro-Fuzzy Inference System guided objective function parameter optimization for inverse treatment planning

Intensity-Modulated Radiation Therapy requires the manual adjustment to numerous treatment plan parameters (TPPs) through a trial-and-error process to deliver precise radiation doses to the target while minimizing exposure to surrounding healthy tissues. The goal is to achieve a dose distribution th...

Full description

Saved in:
Bibliographic Details
Main Authors: Eduardo Cisternas Jiménez, Fang-Fang Yin
Format: Article
Language:English
Published: Frontiers Media S.A. 2025-02-01
Series:Frontiers in Artificial Intelligence
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/frai.2025.1523390/full
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Intensity-Modulated Radiation Therapy requires the manual adjustment to numerous treatment plan parameters (TPPs) through a trial-and-error process to deliver precise radiation doses to the target while minimizing exposure to surrounding healthy tissues. The goal is to achieve a dose distribution that adheres to a prescribed plan tailored to each patient. Developing an automated approach to optimize patient-specific prescriptions is valuable in scenarios where trade-off selection is uncertain and varies among patients. This study presents a proof-of-concept artificial intelligence (AI) system based on an Adaptive Neuro-Fuzzy Inference System (ANFIS) to guide IMRT planning and achieve optimal, patient-specific prescriptions in aligned with a radiation oncologist's treatment objectives. We developed an in-house ANFIS-AI system utilizing Prescription Dose (PD) constraints to guide the optimization process toward achievable prescriptions. Mimicking human planning behavior, the AI system adjusts TPPs, represented as dose-volume constraints, to meet the prescribed dose goals. This process is informed by a Fuzzy Inference System (FIS) that incorporates prior knowledge from experienced planners, captured through “if-then” rules based on routine planning adjustments. The innovative aspect of our research lies in employing ANFIS's adaptive network to fine-tune the FIS components (membership functions and rule strengths), thereby enhancing the accuracy of the system. Once calibrated, the AI system modifies TPPs for each patient, progressing through acceptable prescription levels, from restrictive to clinically allowable. The system evaluates dosimetric parameters and compares dose distributions, dose-volume histograms, and dosimetric statistics between the conventional FIS and ANFIS. Results demonstrate that ANFIS consistently met dosimetric goals, outperforming FIS with a 0.7% improvement in mean dose conformity for the planning target volume (PTV) and a 28% reduction in mean dose exposure for organs at risk (OARs) in a C-Shape phantom. In a mock prostate phantom, ANFIS reduced the mean dose by 17.4% for the rectum and by 14.1% for the bladder. These findings highlight ANFIS's potential for efficient, accurate IMRT planning and its integration into clinical workflows.
ISSN:2624-8212