Investigation on inherent angle ventilation control of residential kitchen range hoods

The emission of oil fume particles during kitchen cooking processes constitutes a significant factor that impacts indoor air quality and human health. Range hoods, as indispensable ventilation devices in kitchens, play a crucial role in reducing indoor particle concentrations. This study employs a c...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhilin Guo, Huixing Li, Guohui Feng, Kailiang Huang, Tengfei Yu
Format: Article
Language:English
Published: KeAi Communications Co., Ltd. 2025-06-01
Series:Energy and Built Environment
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666123324000072
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1825199436702154752
author Zhilin Guo
Huixing Li
Guohui Feng
Kailiang Huang
Tengfei Yu
author_facet Zhilin Guo
Huixing Li
Guohui Feng
Kailiang Huang
Tengfei Yu
author_sort Zhilin Guo
collection DOAJ
description The emission of oil fume particles during kitchen cooking processes constitutes a significant factor that impacts indoor air quality and human health. Range hoods, as indispensable ventilation devices in kitchens, play a crucial role in reducing indoor particle concentrations. This study employs a combined approach of orthogonal experiments and computational fluid dynamics simulations to investigate the exhaust characteristics of inherent-angle-measurement-based range hoods. It analyzes the diffusion patterns of cooking-generated particulate matter under various cooking scenarios, considering factors such as the opening and closing of windows, cooking source velocities, and different airflow rates of the range hood. Based on different airflow organization patterns, a supplementary ventilation system is designed. The rationality and effectiveness of the supplementary ventilation system are analyzed to establish an effective control scheme for reducing particulate matter in various kitchen environments. The simulated research results indicate that particles disperse along the inclined surface of the side-draft range hood, resulting in higher pollutant concentrations in the breathing zone compared to the cooking zone. Increasing the exhaust airflow rate of the range hood enhances particle capture efficiency by 9.8 %. The induced airflow generated by opening windows improves particle capture efficiency by 12.9 %. However, when the velocity of the window-induced airflow exceeds 1.5 m/s, it hampers the promotion of particle capture efficiency. In the case of windows being unconditionally open, implementing a ceiling-mounted supplementary air supply system effectively improves the kitchen's particle concentration, achieving a maximum particle capture efficiency of 97.66 %. When windows can be opened, setting a baffle on the range hood, the simulation results revealed that with a baffle angle of 120° and a length of 0.3 m, the particle concentration capture efficiency in the breathing zone increased by 34.59 %. This achieved the standard limit requirement of 50 µg/m3, thus meeting the indoor air quality requirements.
format Article
id doaj-art-9a522941c8954d7f9c5a15ec54454aad
institution Kabale University
issn 2666-1233
language English
publishDate 2025-06-01
publisher KeAi Communications Co., Ltd.
record_format Article
series Energy and Built Environment
spelling doaj-art-9a522941c8954d7f9c5a15ec54454aad2025-02-08T05:01:11ZengKeAi Communications Co., Ltd.Energy and Built Environment2666-12332025-06-0163432447Investigation on inherent angle ventilation control of residential kitchen range hoodsZhilin Guo0Huixing Li1Guohui Feng2Kailiang Huang3Tengfei Yu4School of Municipal and Environmental Engineering, Shenyang Jianzhu University, Shenyang 110168, ChinaCorresponding author.; School of Municipal and Environmental Engineering, Shenyang Jianzhu University, Shenyang 110168, ChinaSchool of Municipal and Environmental Engineering, Shenyang Jianzhu University, Shenyang 110168, ChinaSchool of Municipal and Environmental Engineering, Shenyang Jianzhu University, Shenyang 110168, ChinaSchool of Municipal and Environmental Engineering, Shenyang Jianzhu University, Shenyang 110168, ChinaThe emission of oil fume particles during kitchen cooking processes constitutes a significant factor that impacts indoor air quality and human health. Range hoods, as indispensable ventilation devices in kitchens, play a crucial role in reducing indoor particle concentrations. This study employs a combined approach of orthogonal experiments and computational fluid dynamics simulations to investigate the exhaust characteristics of inherent-angle-measurement-based range hoods. It analyzes the diffusion patterns of cooking-generated particulate matter under various cooking scenarios, considering factors such as the opening and closing of windows, cooking source velocities, and different airflow rates of the range hood. Based on different airflow organization patterns, a supplementary ventilation system is designed. The rationality and effectiveness of the supplementary ventilation system are analyzed to establish an effective control scheme for reducing particulate matter in various kitchen environments. The simulated research results indicate that particles disperse along the inclined surface of the side-draft range hood, resulting in higher pollutant concentrations in the breathing zone compared to the cooking zone. Increasing the exhaust airflow rate of the range hood enhances particle capture efficiency by 9.8 %. The induced airflow generated by opening windows improves particle capture efficiency by 12.9 %. However, when the velocity of the window-induced airflow exceeds 1.5 m/s, it hampers the promotion of particle capture efficiency. In the case of windows being unconditionally open, implementing a ceiling-mounted supplementary air supply system effectively improves the kitchen's particle concentration, achieving a maximum particle capture efficiency of 97.66 %. When windows can be opened, setting a baffle on the range hood, the simulation results revealed that with a baffle angle of 120° and a length of 0.3 m, the particle concentration capture efficiency in the breathing zone increased by 34.59 %. This achieved the standard limit requirement of 50 µg/m3, thus meeting the indoor air quality requirements.http://www.sciencedirect.com/science/article/pii/S2666123324000072Side-draft exhaust systemNumerical simulationSignificance analysisParticle distributionIndoor air quality control
spellingShingle Zhilin Guo
Huixing Li
Guohui Feng
Kailiang Huang
Tengfei Yu
Investigation on inherent angle ventilation control of residential kitchen range hoods
Energy and Built Environment
Side-draft exhaust system
Numerical simulation
Significance analysis
Particle distribution
Indoor air quality control
title Investigation on inherent angle ventilation control of residential kitchen range hoods
title_full Investigation on inherent angle ventilation control of residential kitchen range hoods
title_fullStr Investigation on inherent angle ventilation control of residential kitchen range hoods
title_full_unstemmed Investigation on inherent angle ventilation control of residential kitchen range hoods
title_short Investigation on inherent angle ventilation control of residential kitchen range hoods
title_sort investigation on inherent angle ventilation control of residential kitchen range hoods
topic Side-draft exhaust system
Numerical simulation
Significance analysis
Particle distribution
Indoor air quality control
url http://www.sciencedirect.com/science/article/pii/S2666123324000072
work_keys_str_mv AT zhilinguo investigationoninherentangleventilationcontrolofresidentialkitchenrangehoods
AT huixingli investigationoninherentangleventilationcontrolofresidentialkitchenrangehoods
AT guohuifeng investigationoninherentangleventilationcontrolofresidentialkitchenrangehoods
AT kailianghuang investigationoninherentangleventilationcontrolofresidentialkitchenrangehoods
AT tengfeiyu investigationoninherentangleventilationcontrolofresidentialkitchenrangehoods