Restoration of Load-Bearing Structures of Buildings after Accidents
The issues of protecting buildings from special, usually non-design, impacts, including progressive collapse as a result of emergency impacts, are the subject of many scientific works and regulatory documents have been developed regulating calculation and design provisions for application at the des...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Moscow State University of Civil Engineering (MGSU)
2024-09-01
|
Series: | Железобетонные конструкции |
Subjects: | |
Online Access: | https://www.g-b-k.ru/jour/article/view/57 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832087164491399168 |
---|---|
author | O. A. Simakov |
author_facet | O. A. Simakov |
author_sort | O. A. Simakov |
collection | DOAJ |
description | The issues of protecting buildings from special, usually non-design, impacts, including progressive collapse as a result of emergency impacts, are the subject of many scientific works and regulatory documents have been developed regulating calculation and design provisions for application at the design stage. At the same time, the issues of strengthening existing buildings and structures at the stages of major repairs, reconstruction (if measures, for example, for protection against progressive collapse were not envisaged at the design stage, then bringing the structures to the requirements of the standards is a complex, often impossible task), as well as restoration of load-bearing structures after emergency situations remain open. In accordance with the current regulatory documents, the calculation for a special limit state is carried out with reduced coefficients for loads and taking into account the dynamic hardening for the design resistance of materials. After an emergency impact, it is necessary to perform a calculation for limit states taking into account all reliability factors, which usually leads to a deficit in the bearing capacity of a significant number of load-bearing structures taking into account the damage to individual structures and the redistribution of forces to others that are not damaged. It is for this operational stage after the special impacts considered in this article that there are no special requirements and assumptions in the operation of the building’s load-bearing structures. |
format | Article |
id | doaj-art-b1a6c4a4153d4b8b85a0e06f511b99d5 |
institution | Kabale University |
issn | 2949-1622 2949-1614 |
language | English |
publishDate | 2024-09-01 |
publisher | Moscow State University of Civil Engineering (MGSU) |
record_format | Article |
series | Железобетонные конструкции |
spelling | doaj-art-b1a6c4a4153d4b8b85a0e06f511b99d52025-02-06T07:09:54ZengMoscow State University of Civil Engineering (MGSU)Железобетонные конструкции2949-16222949-16142024-09-0173344310.22227/2949-1622.2024.3.34-4352Restoration of Load-Bearing Structures of Buildings after AccidentsO. A. Simakov0Moscow State University of Civil Engineering (National Research University) (MGSU)The issues of protecting buildings from special, usually non-design, impacts, including progressive collapse as a result of emergency impacts, are the subject of many scientific works and regulatory documents have been developed regulating calculation and design provisions for application at the design stage. At the same time, the issues of strengthening existing buildings and structures at the stages of major repairs, reconstruction (if measures, for example, for protection against progressive collapse were not envisaged at the design stage, then bringing the structures to the requirements of the standards is a complex, often impossible task), as well as restoration of load-bearing structures after emergency situations remain open. In accordance with the current regulatory documents, the calculation for a special limit state is carried out with reduced coefficients for loads and taking into account the dynamic hardening for the design resistance of materials. After an emergency impact, it is necessary to perform a calculation for limit states taking into account all reliability factors, which usually leads to a deficit in the bearing capacity of a significant number of load-bearing structures taking into account the damage to individual structures and the redistribution of forces to others that are not damaged. It is for this operational stage after the special impacts considered in this article that there are no special requirements and assumptions in the operation of the building’s load-bearing structures.https://www.g-b-k.ru/jour/article/view/57restorationstrengtheningspecial limit statesaccident |
spellingShingle | O. A. Simakov Restoration of Load-Bearing Structures of Buildings after Accidents Железобетонные конструкции restoration strengthening special limit states accident |
title | Restoration of Load-Bearing Structures of Buildings after Accidents |
title_full | Restoration of Load-Bearing Structures of Buildings after Accidents |
title_fullStr | Restoration of Load-Bearing Structures of Buildings after Accidents |
title_full_unstemmed | Restoration of Load-Bearing Structures of Buildings after Accidents |
title_short | Restoration of Load-Bearing Structures of Buildings after Accidents |
title_sort | restoration of load bearing structures of buildings after accidents |
topic | restoration strengthening special limit states accident |
url | https://www.g-b-k.ru/jour/article/view/57 |
work_keys_str_mv | AT oasimakov restorationofloadbearingstructuresofbuildingsafteraccidents |