Ten hour donor heart ischemic time with 10ºC static storage

Utilization of 10ºC static storage safely extended both ischemic time and travel radius in heart transplantation. A 57-year-old man with ischemic cardiomyopathy, a left ventricular assist device (LVAD), and end-stage renal disease was listed for combined heart-kidney transplant. The donor hospital i...

Full description

Saved in:
Bibliographic Details
Main Authors: William Tucker, MD, Yatrik Patel, MD, Mark Petrovic, MS, Chris Schwartz, RN, Brandon Petree, DO, Steve Devries, DMSc, PA-C, Brian Lima, MD, John Trahanas, MD, Matthew Bacchetta, MD, MBA, Ashish Shah, MD, Swaroop Bommareddi, MD
Format: Article
Language:English
Published: Elsevier 2025-02-01
Series:JHLT Open
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2950133424001125
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823864278217654272
author William Tucker, MD
Yatrik Patel, MD
Mark Petrovic, MS
Chris Schwartz, RN
Brandon Petree, DO
Steve Devries, DMSc, PA-C
Brian Lima, MD
John Trahanas, MD
Matthew Bacchetta, MD, MBA
Ashish Shah, MD
Swaroop Bommareddi, MD
author_facet William Tucker, MD
Yatrik Patel, MD
Mark Petrovic, MS
Chris Schwartz, RN
Brandon Petree, DO
Steve Devries, DMSc, PA-C
Brian Lima, MD
John Trahanas, MD
Matthew Bacchetta, MD, MBA
Ashish Shah, MD
Swaroop Bommareddi, MD
author_sort William Tucker, MD
collection DOAJ
description Utilization of 10ºC static storage safely extended both ischemic time and travel radius in heart transplantation. A 57-year-old man with ischemic cardiomyopathy, a left ventricular assist device (LVAD), and end-stage renal disease was listed for combined heart-kidney transplant. The donor hospital in Anchorage, AK, was located approximately 2,700 nautical miles and 8 hours from the recipient center. The organ was transported in 10ºC static storage with over 10 hours of ischemic time and had superb early allograft function. Excellent outcomes with extended ischemic times can be achieved without machine perfusion, provided good recovery, storage, and implant techniques are followed.
format Article
id doaj-art-d3ea39ebed8d449d8103e97727074f96
institution Kabale University
issn 2950-1334
language English
publishDate 2025-02-01
publisher Elsevier
record_format Article
series JHLT Open
spelling doaj-art-d3ea39ebed8d449d8103e97727074f962025-02-09T05:01:52ZengElsevierJHLT Open2950-13342025-02-017100163Ten hour donor heart ischemic time with 10ºC static storageWilliam Tucker, MD0Yatrik Patel, MD1Mark Petrovic, MS2Chris Schwartz, RN3Brandon Petree, DO4Steve Devries, DMSc, PA-C5Brian Lima, MD6John Trahanas, MD7Matthew Bacchetta, MD, MBA8Ashish Shah, MD9Swaroop Bommareddi, MD10Vanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, Tennessee; Corresponding author: William Tucker, MD, Vanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, Tennessee.Vanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeVanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeVanderbilt University Medical Center, Office of Transplant Procurement and Preservation, Nashville, TennesseeVanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeVanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeVanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeVanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeVanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeVanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeVanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, TennesseeUtilization of 10ºC static storage safely extended both ischemic time and travel radius in heart transplantation. A 57-year-old man with ischemic cardiomyopathy, a left ventricular assist device (LVAD), and end-stage renal disease was listed for combined heart-kidney transplant. The donor hospital in Anchorage, AK, was located approximately 2,700 nautical miles and 8 hours from the recipient center. The organ was transported in 10ºC static storage with over 10 hours of ischemic time and had superb early allograft function. Excellent outcomes with extended ischemic times can be achieved without machine perfusion, provided good recovery, storage, and implant techniques are followed.http://www.sciencedirect.com/science/article/pii/S2950133424001125heart transplantprolonged ischemiaheart failureorgan preservation
spellingShingle William Tucker, MD
Yatrik Patel, MD
Mark Petrovic, MS
Chris Schwartz, RN
Brandon Petree, DO
Steve Devries, DMSc, PA-C
Brian Lima, MD
John Trahanas, MD
Matthew Bacchetta, MD, MBA
Ashish Shah, MD
Swaroop Bommareddi, MD
Ten hour donor heart ischemic time with 10ºC static storage
JHLT Open
heart transplant
prolonged ischemia
heart failure
organ preservation
title Ten hour donor heart ischemic time with 10ºC static storage
title_full Ten hour donor heart ischemic time with 10ºC static storage
title_fullStr Ten hour donor heart ischemic time with 10ºC static storage
title_full_unstemmed Ten hour donor heart ischemic time with 10ºC static storage
title_short Ten hour donor heart ischemic time with 10ºC static storage
title_sort ten hour donor heart ischemic time with 10ºc static storage
topic heart transplant
prolonged ischemia
heart failure
organ preservation
url http://www.sciencedirect.com/science/article/pii/S2950133424001125
work_keys_str_mv AT williamtuckermd tenhourdonorheartischemictimewith10ocstaticstorage
AT yatrikpatelmd tenhourdonorheartischemictimewith10ocstaticstorage
AT markpetrovicms tenhourdonorheartischemictimewith10ocstaticstorage
AT chrisschwartzrn tenhourdonorheartischemictimewith10ocstaticstorage
AT brandonpetreedo tenhourdonorheartischemictimewith10ocstaticstorage
AT stevedevriesdmscpac tenhourdonorheartischemictimewith10ocstaticstorage
AT brianlimamd tenhourdonorheartischemictimewith10ocstaticstorage
AT johntrahanasmd tenhourdonorheartischemictimewith10ocstaticstorage
AT matthewbacchettamdmba tenhourdonorheartischemictimewith10ocstaticstorage
AT ashishshahmd tenhourdonorheartischemictimewith10ocstaticstorage
AT swaroopbommareddimd tenhourdonorheartischemictimewith10ocstaticstorage