The efficiency of galvanic wastewater treatment facility 'Frad' in Aleksinac

The technological process of Galvano-chemical protection, according to qualitatively-quantitative characteristics, represents one of the most complex contaminants in wastewater. A large number of contaminants (metal ions, cyanides, acids, bases, grease and oils, organic solvents, surfactants, phosph...

Full description

Saved in:
Bibliographic Details
Main Authors: Veličković Jasmina, Arsić Nebojša B., Stošić Ljiljana
Format: Article
Language:English
Published: Visoka poslovna škola strukovnih studija Prof. dr Radomir Bojković, Kruševac 2020-01-01
Series:Trendovi u Poslovanju
Subjects:
Online Access:https://scindeks-clanci.ceon.rs/data/pdf/2334-816X/2020/2334-816X2002078V.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823859947983601664
author Veličković Jasmina
Arsić Nebojša B.
Stošić Ljiljana
author_facet Veličković Jasmina
Arsić Nebojša B.
Stošić Ljiljana
author_sort Veličković Jasmina
collection DOAJ
description The technological process of Galvano-chemical protection, according to qualitatively-quantitative characteristics, represents one of the most complex contaminants in wastewater. A large number of contaminants (metal ions, cyanides, acids, bases, grease and oils, organic solvents, surfactants, phosphates, etc.), found in galvanic wastewater are treated through conventional methods (chemical oxidation and reduction, neutralization, sedimentation, coagulation and flocculation). The reason why galvanic wastewater treatment systems in the Republic of Serbia are conventional is of economic nature. The present study has been undertaken to evaluate the performance of Sewage Treatment Plant located at Aleksinac, Company of "Frad" district which is based on Sequential Batch Reactor process. Performance of this plant is an essential parameter to be monitored as the treated effluent is discharged into the Moravica River. The Performance Evaluation will also help for the better understanding of design and operating difficulties (aeration, blowers, etc.) in Sewage Treatment Plant. Research goal: The efficiency of sewage treatment plants can be illustrated by a study on the evaluation of pollutant levels of the influent and the effluent at the treatment plant of sewage treatment plants discharging into the environment.
format Article
id doaj-art-e91564146780465e9a986cbb179c9818
institution Kabale University
issn 2334-816X
2334-8356
language English
publishDate 2020-01-01
publisher Visoka poslovna škola strukovnih studija Prof. dr Radomir Bojković, Kruševac
record_format Article
series Trendovi u Poslovanju
spelling doaj-art-e91564146780465e9a986cbb179c98182025-02-10T19:38:24ZengVisoka poslovna škola strukovnih studija Prof. dr Radomir Bojković, KruševacTrendovi u Poslovanju2334-816X2334-83562020-01-018278852334-816X2002078VThe efficiency of galvanic wastewater treatment facility 'Frad' in AleksinacVeličković Jasmina0Arsić Nebojša B.1Stošić Ljiljana2Higher business school of vocational studies "Radomir Bojkovic PhD", Krusevac, SerbiaŠumadija Academy of Professional Studies, Faculty of Technology, Department Kruševac, Krusevac, SerbiaPublic Health Institute, Niš, SerbiaThe technological process of Galvano-chemical protection, according to qualitatively-quantitative characteristics, represents one of the most complex contaminants in wastewater. A large number of contaminants (metal ions, cyanides, acids, bases, grease and oils, organic solvents, surfactants, phosphates, etc.), found in galvanic wastewater are treated through conventional methods (chemical oxidation and reduction, neutralization, sedimentation, coagulation and flocculation). The reason why galvanic wastewater treatment systems in the Republic of Serbia are conventional is of economic nature. The present study has been undertaken to evaluate the performance of Sewage Treatment Plant located at Aleksinac, Company of "Frad" district which is based on Sequential Batch Reactor process. Performance of this plant is an essential parameter to be monitored as the treated effluent is discharged into the Moravica River. The Performance Evaluation will also help for the better understanding of design and operating difficulties (aeration, blowers, etc.) in Sewage Treatment Plant. Research goal: The efficiency of sewage treatment plants can be illustrated by a study on the evaluation of pollutant levels of the influent and the effluent at the treatment plant of sewage treatment plants discharging into the environment.https://scindeks-clanci.ceon.rs/data/pdf/2334-816X/2020/2334-816X2002078V.pdfwastewatergalvanic water treatmentgalvano-chemical protection
spellingShingle Veličković Jasmina
Arsić Nebojša B.
Stošić Ljiljana
The efficiency of galvanic wastewater treatment facility 'Frad' in Aleksinac
Trendovi u Poslovanju
wastewater
galvanic water treatment
galvano-chemical protection
title The efficiency of galvanic wastewater treatment facility 'Frad' in Aleksinac
title_full The efficiency of galvanic wastewater treatment facility 'Frad' in Aleksinac
title_fullStr The efficiency of galvanic wastewater treatment facility 'Frad' in Aleksinac
title_full_unstemmed The efficiency of galvanic wastewater treatment facility 'Frad' in Aleksinac
title_short The efficiency of galvanic wastewater treatment facility 'Frad' in Aleksinac
title_sort efficiency of galvanic wastewater treatment facility frad in aleksinac
topic wastewater
galvanic water treatment
galvano-chemical protection
url https://scindeks-clanci.ceon.rs/data/pdf/2334-816X/2020/2334-816X2002078V.pdf
work_keys_str_mv AT velickovicjasmina theefficiencyofgalvanicwastewatertreatmentfacilityfradinaleksinac
AT arsicnebojsab theefficiencyofgalvanicwastewatertreatmentfacilityfradinaleksinac
AT stosicljiljana theefficiencyofgalvanicwastewatertreatmentfacilityfradinaleksinac
AT velickovicjasmina efficiencyofgalvanicwastewatertreatmentfacilityfradinaleksinac
AT arsicnebojsab efficiencyofgalvanicwastewatertreatmentfacilityfradinaleksinac
AT stosicljiljana efficiencyofgalvanicwastewatertreatmentfacilityfradinaleksinac