UPFC Subsynchronous Oscillation Suppression Strategy Based on Linear Active Disturbance Rejection Control

Large-scale doubly-fed wind farms connected through series-compensated transmission lines are prone to subsynchronous oscillations (SSO), which can cause wind turbines to disconnect from the grid, posing a serious threat to the safe and stable operation of the power system. This paper proposes a con...

Full description

Saved in:
Bibliographic Details
Main Author: LIU Yiqi, HUANG Xu, WANG Tianhao, ZHENG Junyuan
Format: Article
Language:zho
Published: Editorial Department of Electric Power Construction 2025-02-01
Series:Dianli jianshe
Subjects:
Online Access:https://www.cepc.com.cn/fileup/1000-7229/PDF/1738997565568-887208073.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823860926954078208
author LIU Yiqi, HUANG Xu, WANG Tianhao, ZHENG Junyuan
author_facet LIU Yiqi, HUANG Xu, WANG Tianhao, ZHENG Junyuan
author_sort LIU Yiqi, HUANG Xu, WANG Tianhao, ZHENG Junyuan
collection DOAJ
description Large-scale doubly-fed wind farms connected through series-compensated transmission lines are prone to subsynchronous oscillations (SSO), which can cause wind turbines to disconnect from the grid, posing a serious threat to the safe and stable operation of the power system. This paper proposes a control method that utilizes a unified power flow controller (UPFC) with additional damping control to mitigate SSO. The approach involves the design of a decoupled linear active disturbance rejection controller (LADRC) that uses a linear state observer to estimate the subsynchronous disturbances in the system in real time. In addition, a delay-compensation mechanism was introduced to eliminate communication delays during signal transmission. Based on the improved LADRC, an additional damping controller for the UPFC was designed to enable the UPFC to exhibit positive damping characteristics in the system, thereby suppressing SSO and enhancing the robustness and resistance of the system to disturbances. Finally, a simulation model of a doubly-fed wind farm connected to the grid through a series-compensated transmission line was developed using the MATLAB/Simulink software. The simulation results demonstrate that the proposed method effectively mitigates SSO under various conditions, including different levels of series compensation, wind speeds, and numbers of connected wind turbines. This can serve as a reference for studying similar problems of long-distance grid connections in double-fed wind farms in China.
format Article
id doaj-art-e9922be98b9345bd95b1e90ccc883243
institution Kabale University
issn 1000-7229
language zho
publishDate 2025-02-01
publisher Editorial Department of Electric Power Construction
record_format Article
series Dianli jianshe
spelling doaj-art-e9922be98b9345bd95b1e90ccc8832432025-02-10T09:54:54ZzhoEditorial Department of Electric Power ConstructionDianli jianshe1000-72292025-02-0146215115910.12204/j.issn.1000-7229.2025.02.013UPFC Subsynchronous Oscillation Suppression Strategy Based on Linear Active Disturbance Rejection ControlLIU Yiqi, HUANG Xu, WANG Tianhao, ZHENG Junyuan0College of Computer and Control Engineering, Northeast Forestry University, Harbin 150040, ChinaLarge-scale doubly-fed wind farms connected through series-compensated transmission lines are prone to subsynchronous oscillations (SSO), which can cause wind turbines to disconnect from the grid, posing a serious threat to the safe and stable operation of the power system. This paper proposes a control method that utilizes a unified power flow controller (UPFC) with additional damping control to mitigate SSO. The approach involves the design of a decoupled linear active disturbance rejection controller (LADRC) that uses a linear state observer to estimate the subsynchronous disturbances in the system in real time. In addition, a delay-compensation mechanism was introduced to eliminate communication delays during signal transmission. Based on the improved LADRC, an additional damping controller for the UPFC was designed to enable the UPFC to exhibit positive damping characteristics in the system, thereby suppressing SSO and enhancing the robustness and resistance of the system to disturbances. Finally, a simulation model of a doubly-fed wind farm connected to the grid through a series-compensated transmission line was developed using the MATLAB/Simulink software. The simulation results demonstrate that the proposed method effectively mitigates SSO under various conditions, including different levels of series compensation, wind speeds, and numbers of connected wind turbines. This can serve as a reference for studying similar problems of long-distance grid connections in double-fed wind farms in China.https://www.cepc.com.cn/fileup/1000-7229/PDF/1738997565568-887208073.pdfdouble-fed wind farm|series-compensated transmission lines|sub-synchronous oscillation(sso)|linear active disturbance rejection control(ladrc)
spellingShingle LIU Yiqi, HUANG Xu, WANG Tianhao, ZHENG Junyuan
UPFC Subsynchronous Oscillation Suppression Strategy Based on Linear Active Disturbance Rejection Control
Dianli jianshe
double-fed wind farm|series-compensated transmission lines|sub-synchronous oscillation(sso)|linear active disturbance rejection control(ladrc)
title UPFC Subsynchronous Oscillation Suppression Strategy Based on Linear Active Disturbance Rejection Control
title_full UPFC Subsynchronous Oscillation Suppression Strategy Based on Linear Active Disturbance Rejection Control
title_fullStr UPFC Subsynchronous Oscillation Suppression Strategy Based on Linear Active Disturbance Rejection Control
title_full_unstemmed UPFC Subsynchronous Oscillation Suppression Strategy Based on Linear Active Disturbance Rejection Control
title_short UPFC Subsynchronous Oscillation Suppression Strategy Based on Linear Active Disturbance Rejection Control
title_sort upfc subsynchronous oscillation suppression strategy based on linear active disturbance rejection control
topic double-fed wind farm|series-compensated transmission lines|sub-synchronous oscillation(sso)|linear active disturbance rejection control(ladrc)
url https://www.cepc.com.cn/fileup/1000-7229/PDF/1738997565568-887208073.pdf
work_keys_str_mv AT liuyiqihuangxuwangtianhaozhengjunyuan upfcsubsynchronousoscillationsuppressionstrategybasedonlinearactivedisturbancerejectioncontrol