The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro study
Abstract Background A recurring issue during orthodontic treatment is the detachment of brackets from the tooth surface, which proves problematic for both the patient and the orthodontist. This study aimed to evaluate the impact of various temperatures on the shear bond strength of metal molar tubes...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2025-02-01
|
Series: | BMC Oral Health |
Subjects: | |
Online Access: | https://doi.org/10.1186/s12903-025-05515-3 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1823861605673205760 |
---|---|
author | Grėtė Kazlauskaitė Rytis Vaitiekūnas Kristina Lopatienė Audrius Jutas Benedikta Palesik Dalia Smailienė |
author_facet | Grėtė Kazlauskaitė Rytis Vaitiekūnas Kristina Lopatienė Audrius Jutas Benedikta Palesik Dalia Smailienė |
author_sort | Grėtė Kazlauskaitė |
collection | DOAJ |
description | Abstract Background A recurring issue during orthodontic treatment is the detachment of brackets from the tooth surface, which proves problematic for both the patient and the orthodontist. This study aimed to evaluate the impact of various temperatures on the shear bond strength of metal molar tubes, using conventional multi-step and self-adhesive orthodontic adhesive systems. Methods A total of 112 extracted human molars were randomly divided into eight groups (n = 14) for bonding tubes with two orthodontic adhesive systems (Transbond XT and GC Ortho Connect) at different temperatures: refrigeration temperature (4 °C), room temperature (20 °C), human body temperature (37 °C), and high temperature (55 °C). The shear bond strength (SBS) test was conducted using a universal testing machine set to a crosshead speed of 0.5 mm/min. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remnants on the molar surfaces. ARI scores were assessed under Carl Zeiss Stemi 2000-CS stereomicroscope with image recording camera AxioCam Mrc5 at ×10 magnification. The data were analyzed using Student’s t-test, parametric analysis of variance (ANOVA), the intra-class correlation coefficient (ICC), the Kruskal-Wallis test, and the chi-square test. Results Higher mean SBS values were obtained with Transbond XT compared to GC Ortho Connect resin; however, the difference was not statistically significant (p > 0.05). The SBS results were lowest at 20 °C and highest at 55 °C in the Transbond XT group, and lowest at 37 °C and highest at 20 °C in the GC Ortho Connect group with no statistically significant difference (p > 0.05). The distribution of the ARI scores between the two materials showed a statistically significant difference (p = 0.002), with higher ARI scores found in the Transbond XT group. Conclusions Pre-heating orthodontic adhesives prior to bonding does not affect the shear bond strength. |
format | Article |
id | doaj-art-eee3ae4d813245189a5f7b9ebc29b186 |
institution | Kabale University |
issn | 1472-6831 |
language | English |
publishDate | 2025-02-01 |
publisher | BMC |
record_format | Article |
series | BMC Oral Health |
spelling | doaj-art-eee3ae4d813245189a5f7b9ebc29b1862025-02-09T12:57:04ZengBMCBMC Oral Health1472-68312025-02-012511910.1186/s12903-025-05515-3The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro studyGrėtė Kazlauskaitė0Rytis Vaitiekūnas1Kristina Lopatienė2Audrius Jutas3Benedikta Palesik4Dalia Smailienė5Faculty of Odontology, Medical Academy, Lithuanian University of Health SciencesFaculty of Odontology, Medical Academy, Lithuanian University of Health SciencesDepartment of Orthodontics, Faculty of Odontology, Lithuanian University of Health SciencesDepartment of Mechanical Engineering, Faculty of Mechanical Engineering and Design, Kaunas University of TechnologyDepartment of Orthodontics, Faculty of Odontology, Lithuanian University of Health SciencesDepartment of Orthodontics, Faculty of Odontology, Lithuanian University of Health SciencesAbstract Background A recurring issue during orthodontic treatment is the detachment of brackets from the tooth surface, which proves problematic for both the patient and the orthodontist. This study aimed to evaluate the impact of various temperatures on the shear bond strength of metal molar tubes, using conventional multi-step and self-adhesive orthodontic adhesive systems. Methods A total of 112 extracted human molars were randomly divided into eight groups (n = 14) for bonding tubes with two orthodontic adhesive systems (Transbond XT and GC Ortho Connect) at different temperatures: refrigeration temperature (4 °C), room temperature (20 °C), human body temperature (37 °C), and high temperature (55 °C). The shear bond strength (SBS) test was conducted using a universal testing machine set to a crosshead speed of 0.5 mm/min. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remnants on the molar surfaces. ARI scores were assessed under Carl Zeiss Stemi 2000-CS stereomicroscope with image recording camera AxioCam Mrc5 at ×10 magnification. The data were analyzed using Student’s t-test, parametric analysis of variance (ANOVA), the intra-class correlation coefficient (ICC), the Kruskal-Wallis test, and the chi-square test. Results Higher mean SBS values were obtained with Transbond XT compared to GC Ortho Connect resin; however, the difference was not statistically significant (p > 0.05). The SBS results were lowest at 20 °C and highest at 55 °C in the Transbond XT group, and lowest at 37 °C and highest at 20 °C in the GC Ortho Connect group with no statistically significant difference (p > 0.05). The distribution of the ARI scores between the two materials showed a statistically significant difference (p = 0.002), with higher ARI scores found in the Transbond XT group. Conclusions Pre-heating orthodontic adhesives prior to bonding does not affect the shear bond strength.https://doi.org/10.1186/s12903-025-05515-3Shear bond strengthOrthodontic adhesivesTemperature |
spellingShingle | Grėtė Kazlauskaitė Rytis Vaitiekūnas Kristina Lopatienė Audrius Jutas Benedikta Palesik Dalia Smailienė The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro study BMC Oral Health Shear bond strength Orthodontic adhesives Temperature |
title | The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro study |
title_full | The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro study |
title_fullStr | The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro study |
title_full_unstemmed | The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro study |
title_short | The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro study |
title_sort | impact of temperature on the shear bond strength of conventional multi step and self adhesive orthodontic adhesive systems an in vitro study |
topic | Shear bond strength Orthodontic adhesives Temperature |
url | https://doi.org/10.1186/s12903-025-05515-3 |
work_keys_str_mv | AT gretekazlauskaite theimpactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT rytisvaitiekunas theimpactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT kristinalopatiene theimpactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT audriusjutas theimpactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT benediktapalesik theimpactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT daliasmailiene theimpactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT gretekazlauskaite impactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT rytisvaitiekunas impactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT kristinalopatiene impactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT audriusjutas impactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT benediktapalesik impactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy AT daliasmailiene impactoftemperatureontheshearbondstrengthofconventionalmultistepandselfadhesiveorthodonticadhesivesystemsaninvitrostudy |