Evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leads

Abstract Aim The aim of the study was to compare the efficacy of single or double lead in percutaneous spinal cord stimulation (SCS). Method Follow-up data of 41 patients (20 patients with double lead, 21 patients with single lead) who underwent percutaneous SCS were analysed. Demographic and clinic...

Full description

Saved in:
Bibliographic Details
Main Authors: Esra Ertilav, Osman Nuri Aydin
Format: Article
Language:English
Published: SpringerOpen 2025-02-01
Series:Egyptian Journal of Neurosurgery
Subjects:
Online Access:https://doi.org/10.1186/s41984-025-00351-7
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823862858432118784
author Esra Ertilav
Osman Nuri Aydin
author_facet Esra Ertilav
Osman Nuri Aydin
author_sort Esra Ertilav
collection DOAJ
description Abstract Aim The aim of the study was to compare the efficacy of single or double lead in percutaneous spinal cord stimulation (SCS). Method Follow-up data of 41 patients (20 patients with double lead, 21 patients with single lead) who underwent percutaneous SCS were analysed. Demographic and clinical examination findings (gender, age, pain characteristic, neurological examination, medications used) and visual analogue scale (VAS) scores were recorded. VAS pain scores, clinical and neurological examination and complication findings were recorded at 1st and 12th months at post-procedure follow-up. Results Twenty patients had double lead and 21 patients had single lead. Five patients had root avulsion, 1 patient had complex regional pain syndrome, 1 patient had postherpetic neuralgia, 2 patients had phantom pain, 3 patients had ischaemic pain and 29 patients had postlaminectomy syndrome. In 10 patients, leads were placed in the cervical region and in 31 patients in the thoracic region. There was at least 50% reduction in VAS scores in 71.4% (15 patients) with single lead implantation and 65% (13 patients) with double lead implantation (p = 0.7). Infection was significantly higher in patients with double lead than in patients with single lead implantation (p < 0.05). In 1 patient, generator exchange was performed because the generator was exposed due to skin necrosis. No major complication was recorded. Conclusion SCS with single and double lead is an effective method in chronic pain syndromes. SCS with single lead can be preferred in terms of time, cost and labour saving.
format Article
id doaj-art-f36399f7af6e46b796330d75d7fe0ca6
institution Kabale University
issn 2520-8225
language English
publishDate 2025-02-01
publisher SpringerOpen
record_format Article
series Egyptian Journal of Neurosurgery
spelling doaj-art-f36399f7af6e46b796330d75d7fe0ca62025-02-09T12:25:16ZengSpringerOpenEgyptian Journal of Neurosurgery2520-82252025-02-014011510.1186/s41984-025-00351-7Evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leadsEsra Ertilav0Osman Nuri Aydin1Department of Neurology, Algology, Adnan Menderes University Medical FacultyDepartment of Anesthesiology, Algology, Adnan Menderes University Medical FacultyAbstract Aim The aim of the study was to compare the efficacy of single or double lead in percutaneous spinal cord stimulation (SCS). Method Follow-up data of 41 patients (20 patients with double lead, 21 patients with single lead) who underwent percutaneous SCS were analysed. Demographic and clinical examination findings (gender, age, pain characteristic, neurological examination, medications used) and visual analogue scale (VAS) scores were recorded. VAS pain scores, clinical and neurological examination and complication findings were recorded at 1st and 12th months at post-procedure follow-up. Results Twenty patients had double lead and 21 patients had single lead. Five patients had root avulsion, 1 patient had complex regional pain syndrome, 1 patient had postherpetic neuralgia, 2 patients had phantom pain, 3 patients had ischaemic pain and 29 patients had postlaminectomy syndrome. In 10 patients, leads were placed in the cervical region and in 31 patients in the thoracic region. There was at least 50% reduction in VAS scores in 71.4% (15 patients) with single lead implantation and 65% (13 patients) with double lead implantation (p = 0.7). Infection was significantly higher in patients with double lead than in patients with single lead implantation (p < 0.05). In 1 patient, generator exchange was performed because the generator was exposed due to skin necrosis. No major complication was recorded. Conclusion SCS with single and double lead is an effective method in chronic pain syndromes. SCS with single lead can be preferred in terms of time, cost and labour saving.https://doi.org/10.1186/s41984-025-00351-7Spinal cord stimulationFailed back surgeryComplex regional pain syndromePain management
spellingShingle Esra Ertilav
Osman Nuri Aydin
Evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leads
Egyptian Journal of Neurosurgery
Spinal cord stimulation
Failed back surgery
Complex regional pain syndrome
Pain management
title Evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leads
title_full Evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leads
title_fullStr Evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leads
title_full_unstemmed Evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leads
title_short Evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leads
title_sort evaluation of the efficacy of percutaneous spinal cord stimulation according to the single or double leads
topic Spinal cord stimulation
Failed back surgery
Complex regional pain syndrome
Pain management
url https://doi.org/10.1186/s41984-025-00351-7
work_keys_str_mv AT esraertilav evaluationoftheefficacyofpercutaneousspinalcordstimulationaccordingtothesingleordoubleleads
AT osmannuriaydin evaluationoftheefficacyofpercutaneousspinalcordstimulationaccordingtothesingleordoubleleads