Evaluation of the penetration depth of Guttaflow bioseal and Bioceramic sealers using scanning electron microscope (in vitro study).

Background and objective: Three- dimensional obturation of the canal is mandatory in root canal treatment to decrease failure rate, the major cause of root canal reinfection after obturation is insufficient obturation of the canal which later leads to a periapical lesion and reinfection.This stu...

Full description

Saved in:
Bibliographic Details
Main Author: Razawa Kareem Saeed
Format: Article
Language:English
Published: College Of Dentistry Hawler Medical University 2024-01-01
Series:Erbil Dental Journal
Subjects:
Online Access:https://edj.hmu.edu.krd/index.php/journal/article/view/248
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823859804692545536
author Razawa Kareem Saeed
author_facet Razawa Kareem Saeed
author_sort Razawa Kareem Saeed
collection DOAJ
description Background and objective: Three- dimensional obturation of the canal is mandatory in root canal treatment to decrease failure rate, the major cause of root canal reinfection after obturation is insufficient obturation of the canal which later leads to a periapical lesion and reinfection.This study aimed to evaluate the penetration depth of Guttaflow bioseal and Bioceramic sealer. Methods: Twenty extracted single-rooted human teeth (mandibular first premolar) were used in this study, teeth were decornated leaving 10 mm root length. The chemico-mechanical preparation of the samples was done by using a protaper universal system till size F1 and then samples were divided into 2 groups (n = 10), according to the filling material in the first group Guttaflow bioseal used while in the second group Onefil bioceramic sealer used the sealers introduced into canals according to manufacturer instructions and then obturated with gutta-percha size F1, single condensation technique used and finally samples were cross-sectioned at 3 and 7 mm, sealers penetration depth was measured by using scanning electron microscope. Result: Independent sample t-test shows that the difference between the penetration depth of guttaflow bioseal and bioceramic sealers are non-significant while the ANOVA test shows that the difference between the three sections of the root is highly significant for both sealer, coronal section shows the best result for Guttaflow bioseal while middle section for Bioceramic shows the best result of penetration. Conclusion: There are no difference in sealer penetration of both sealers Guttaflow bioseal and Onefil bioceramic, while regarding sealer penetration in each sections of root for Guttaflow bioseal in coronal section shows a best penetration, for Onefil bioceramic middle section shows a best penetration.
format Article
id doaj-art-fd1c20da7fbd4caf930bb2583b1fcd88
institution Kabale University
issn 2523-6172
2616-4795
language English
publishDate 2024-01-01
publisher College Of Dentistry Hawler Medical University
record_format Article
series Erbil Dental Journal
spelling doaj-art-fd1c20da7fbd4caf930bb2583b1fcd882025-02-10T20:48:05ZengCollege Of Dentistry Hawler Medical UniversityErbil Dental Journal2523-61722616-47952024-01-0162Evaluation of the penetration depth of Guttaflow bioseal and Bioceramic sealers using scanning electron microscope (in vitro study).Razawa Kareem Saeed0Department of Conservative Dentistry, College of Dentistry, Hawler Medical University, Erbil, Iraqi Kurdistan Region. Background and objective: Three- dimensional obturation of the canal is mandatory in root canal treatment to decrease failure rate, the major cause of root canal reinfection after obturation is insufficient obturation of the canal which later leads to a periapical lesion and reinfection.This study aimed to evaluate the penetration depth of Guttaflow bioseal and Bioceramic sealer. Methods: Twenty extracted single-rooted human teeth (mandibular first premolar) were used in this study, teeth were decornated leaving 10 mm root length. The chemico-mechanical preparation of the samples was done by using a protaper universal system till size F1 and then samples were divided into 2 groups (n = 10), according to the filling material in the first group Guttaflow bioseal used while in the second group Onefil bioceramic sealer used the sealers introduced into canals according to manufacturer instructions and then obturated with gutta-percha size F1, single condensation technique used and finally samples were cross-sectioned at 3 and 7 mm, sealers penetration depth was measured by using scanning electron microscope. Result: Independent sample t-test shows that the difference between the penetration depth of guttaflow bioseal and bioceramic sealers are non-significant while the ANOVA test shows that the difference between the three sections of the root is highly significant for both sealer, coronal section shows the best result for Guttaflow bioseal while middle section for Bioceramic shows the best result of penetration. Conclusion: There are no difference in sealer penetration of both sealers Guttaflow bioseal and Onefil bioceramic, while regarding sealer penetration in each sections of root for Guttaflow bioseal in coronal section shows a best penetration, for Onefil bioceramic middle section shows a best penetration. https://edj.hmu.edu.krd/index.php/journal/article/view/248Penetration depthGuttaflow biosealBioceramic SealerScanning Electron Microscope
spellingShingle Razawa Kareem Saeed
Evaluation of the penetration depth of Guttaflow bioseal and Bioceramic sealers using scanning electron microscope (in vitro study).
Erbil Dental Journal
Penetration depth
Guttaflow bioseal
Bioceramic Sealer
Scanning Electron Microscope
title Evaluation of the penetration depth of Guttaflow bioseal and Bioceramic sealers using scanning electron microscope (in vitro study).
title_full Evaluation of the penetration depth of Guttaflow bioseal and Bioceramic sealers using scanning electron microscope (in vitro study).
title_fullStr Evaluation of the penetration depth of Guttaflow bioseal and Bioceramic sealers using scanning electron microscope (in vitro study).
title_full_unstemmed Evaluation of the penetration depth of Guttaflow bioseal and Bioceramic sealers using scanning electron microscope (in vitro study).
title_short Evaluation of the penetration depth of Guttaflow bioseal and Bioceramic sealers using scanning electron microscope (in vitro study).
title_sort evaluation of the penetration depth of guttaflow bioseal and bioceramic sealers using scanning electron microscope in vitro study
topic Penetration depth
Guttaflow bioseal
Bioceramic Sealer
Scanning Electron Microscope
url https://edj.hmu.edu.krd/index.php/journal/article/view/248
work_keys_str_mv AT razawakareemsaeed evaluationofthepenetrationdepthofguttaflowbiosealandbioceramicsealersusingscanningelectronmicroscopeinvitrostudy