Clinical and measurement variables affecting halitosis intensity following cysteine challenge test

Abstract The cysteine challenge test is a reliable and efficient method for halitosis diagnosis and assessing treatment effectiveness by measuring the capacity to produce hydrogen sulfide. However, several aspects related to the test including evaluation timing and total duration following cysteine...

Full description

Saved in:
Bibliographic Details
Main Authors: Wanki Lee, Jung Hwan Jo, Young-Seok Park, Ji Woon Park
Format: Article
Language:English
Published: Nature Portfolio 2025-02-01
Series:Scientific Reports
Subjects:
Online Access:https://doi.org/10.1038/s41598-024-83177-x
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823862359202988032
author Wanki Lee
Jung Hwan Jo
Young-Seok Park
Ji Woon Park
author_facet Wanki Lee
Jung Hwan Jo
Young-Seok Park
Ji Woon Park
author_sort Wanki Lee
collection DOAJ
description Abstract The cysteine challenge test is a reliable and efficient method for halitosis diagnosis and assessing treatment effectiveness by measuring the capacity to produce hydrogen sulfide. However, several aspects related to the test including evaluation timing and total duration following cysteine loading has not been investigated in-depth and a standardized protocol is yet to be established. This observational study compared concentrations of volatile sulfur compounds (VSCs) following cysteine challenge at various time points based on different measurement tools to investigate clinical factors influencing the results. Cysteine challenge (rinsing for 30 s with 5 mL of 6 mM L-cysteine solution) was applied in 100 healthy subjects. VSC concentration of oral cavity gas was analyzed with standard and portable gas chromatography (GC) at 5 time points (before, immediately, 10, 20, and 30 min after cysteine challenge). The Community Periodontal Index of Treatment Needs (CPITN), Winkel’s Tongue Coating Index, and salivary flow rate were assessed. VSC levels significantly increased immediately after cysteine challenge (p < 0.001 for hydrogen sulfide, p < 0.001 with standard GC and p < 0.05 with portable GC for methyl mercaptan). Levels significantly decreased at 10 min after cysteine challenge except for methyl mercaptan measured with standard GC (p < 0.001). Subjects still showing VSCs 20 min after cysteine challenge was less than 15% of those initially positive. The amount of tongue coating showed significant association with methyl mercaptan levels immediately after (β = 0.202, p = 0.049) and 10 min following (β = 0.207, p = 0.045) cysteine challenge and CPITN showed acceptable discriminative power for persistent detection of methyl mercaptan (cut-off = 1.5, AUC = 0.668). Cysteine challenge may enhance the possibility of detecting VSCs during halitosis diagnosis. Standardized test protocols should address measurement timing, tools used, and tongue coating levels as clinical factors influencing VSC detection.
format Article
id doaj-art-fd66704b6fec41b4bbf97f4f3f51a0cc
institution Kabale University
issn 2045-2322
language English
publishDate 2025-02-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj-art-fd66704b6fec41b4bbf97f4f3f51a0cc2025-02-09T12:35:59ZengNature PortfolioScientific Reports2045-23222025-02-0115111110.1038/s41598-024-83177-xClinical and measurement variables affecting halitosis intensity following cysteine challenge testWanki Lee0Jung Hwan Jo1Young-Seok Park2Ji Woon Park3Center for Future Dentistry, School of Dentistry, Seoul National UniversityDepartment of Oral Medicine and Oral Diagnosis, School of Dentistry, Seoul National UniversityCenter for Future Dentistry, School of Dentistry, Seoul National UniversityDental Research Institute, Seoul National UniversityAbstract The cysteine challenge test is a reliable and efficient method for halitosis diagnosis and assessing treatment effectiveness by measuring the capacity to produce hydrogen sulfide. However, several aspects related to the test including evaluation timing and total duration following cysteine loading has not been investigated in-depth and a standardized protocol is yet to be established. This observational study compared concentrations of volatile sulfur compounds (VSCs) following cysteine challenge at various time points based on different measurement tools to investigate clinical factors influencing the results. Cysteine challenge (rinsing for 30 s with 5 mL of 6 mM L-cysteine solution) was applied in 100 healthy subjects. VSC concentration of oral cavity gas was analyzed with standard and portable gas chromatography (GC) at 5 time points (before, immediately, 10, 20, and 30 min after cysteine challenge). The Community Periodontal Index of Treatment Needs (CPITN), Winkel’s Tongue Coating Index, and salivary flow rate were assessed. VSC levels significantly increased immediately after cysteine challenge (p < 0.001 for hydrogen sulfide, p < 0.001 with standard GC and p < 0.05 with portable GC for methyl mercaptan). Levels significantly decreased at 10 min after cysteine challenge except for methyl mercaptan measured with standard GC (p < 0.001). Subjects still showing VSCs 20 min after cysteine challenge was less than 15% of those initially positive. The amount of tongue coating showed significant association with methyl mercaptan levels immediately after (β = 0.202, p = 0.049) and 10 min following (β = 0.207, p = 0.045) cysteine challenge and CPITN showed acceptable discriminative power for persistent detection of methyl mercaptan (cut-off = 1.5, AUC = 0.668). Cysteine challenge may enhance the possibility of detecting VSCs during halitosis diagnosis. Standardized test protocols should address measurement timing, tools used, and tongue coating levels as clinical factors influencing VSC detection.https://doi.org/10.1038/s41598-024-83177-xHalitosisDiagnosisCysteine challengeGas chromatographyTongue coating
spellingShingle Wanki Lee
Jung Hwan Jo
Young-Seok Park
Ji Woon Park
Clinical and measurement variables affecting halitosis intensity following cysteine challenge test
Scientific Reports
Halitosis
Diagnosis
Cysteine challenge
Gas chromatography
Tongue coating
title Clinical and measurement variables affecting halitosis intensity following cysteine challenge test
title_full Clinical and measurement variables affecting halitosis intensity following cysteine challenge test
title_fullStr Clinical and measurement variables affecting halitosis intensity following cysteine challenge test
title_full_unstemmed Clinical and measurement variables affecting halitosis intensity following cysteine challenge test
title_short Clinical and measurement variables affecting halitosis intensity following cysteine challenge test
title_sort clinical and measurement variables affecting halitosis intensity following cysteine challenge test
topic Halitosis
Diagnosis
Cysteine challenge
Gas chromatography
Tongue coating
url https://doi.org/10.1038/s41598-024-83177-x
work_keys_str_mv AT wankilee clinicalandmeasurementvariablesaffectinghalitosisintensityfollowingcysteinechallengetest
AT junghwanjo clinicalandmeasurementvariablesaffectinghalitosisintensityfollowingcysteinechallengetest
AT youngseokpark clinicalandmeasurementvariablesaffectinghalitosisintensityfollowingcysteinechallengetest
AT jiwoonpark clinicalandmeasurementvariablesaffectinghalitosisintensityfollowingcysteinechallengetest