The effect of different fabrication techniques on porosity of cobalt-chromium cast removable partial denture farm works.

Background and Objective: Cobalt-chromium removable partial denture has been in use for years and despite of the advantages that cobalt-chromium provides, it has many disadvantages. In recent years with the development of dentistry science a cobalt-chromium removable partial denture is still used...

Full description

Saved in:
Bibliographic Details
Main Authors: Fryad Mustafa Rasheed, Rizgar Mohammed Ameen Hasan
Format: Article
Language:English
Published: College Of Dentistry Hawler Medical University 2022-12-01
Series:Erbil Dental Journal
Subjects:
Online Access:https://edj.hmu.edu.krd/index.php/journal/article/view/186
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823859805433888768
author Fryad Mustafa Rasheed
Rizgar Mohammed Ameen Hasan
author_facet Fryad Mustafa Rasheed
Rizgar Mohammed Ameen Hasan
author_sort Fryad Mustafa Rasheed
collection DOAJ
description Background and Objective: Cobalt-chromium removable partial denture has been in use for years and despite of the advantages that cobalt-chromium provides, it has many disadvantages. In recent years with the development of dentistry science a cobalt-chromium removable partial denture is still used. The purpose of this study was to evaluate the overall porosity of conventional versus computer-aided design/computer-aided manufactured (CAD/CAM) and 3D-Printed removable partial denture (RPD) frameworks based on tests data analysis, and to evaluate the porosity of each technique’s fabrication of the RPD frameworks. Methods: Thirty ideal maxillary stone cast class II modification 1, divided in to three groups for construction of single palatal strap framework conventionally and digitally. For each group, removable partial dentures (chromium cobalt framework) were constructed conventionally and digitally. After finishing and polishing of the prosthesis, the porosity test was performed for each group and then compared to each other. Results: As for the porosity test, the number of defects after finishing and polishing, shows that there are significant differences between the three groups depending on the value of the (F-test) which is less than (P< 0.01), The maximuim mean result was shown by group III, while the minimum result was shown by group I. Conclusions: Within the limitations of this study, although both 3D-printing and CAD/CAM methods of framework fabrication revealed clinically acceptable adaptation, the conventional cast RPD groups revealed less overall porosity.
format Article
id doaj-art-fd8b9c7c8a5247a6a5b694aec4ad1066
institution Kabale University
issn 2523-6172
2616-4795
language English
publishDate 2022-12-01
publisher College Of Dentistry Hawler Medical University
record_format Article
series Erbil Dental Journal
spelling doaj-art-fd8b9c7c8a5247a6a5b694aec4ad10662025-02-10T20:48:21ZengCollege Of Dentistry Hawler Medical UniversityErbil Dental Journal2523-61722616-47952022-12-0152The effect of different fabrication techniques on porosity of cobalt-chromium cast removable partial denture farm works.Fryad Mustafa Rasheed0Rizgar Mohammed Ameen Hasan1Department of Prosthodontics, College of Dentistry, Hawler Medical University, Erbil, Iraq.Department of Prosthodontics, College of Dentistry, Hawler Medical University, Erbil, Iraq. Background and Objective: Cobalt-chromium removable partial denture has been in use for years and despite of the advantages that cobalt-chromium provides, it has many disadvantages. In recent years with the development of dentistry science a cobalt-chromium removable partial denture is still used. The purpose of this study was to evaluate the overall porosity of conventional versus computer-aided design/computer-aided manufactured (CAD/CAM) and 3D-Printed removable partial denture (RPD) frameworks based on tests data analysis, and to evaluate the porosity of each technique’s fabrication of the RPD frameworks. Methods: Thirty ideal maxillary stone cast class II modification 1, divided in to three groups for construction of single palatal strap framework conventionally and digitally. For each group, removable partial dentures (chromium cobalt framework) were constructed conventionally and digitally. After finishing and polishing of the prosthesis, the porosity test was performed for each group and then compared to each other. Results: As for the porosity test, the number of defects after finishing and polishing, shows that there are significant differences between the three groups depending on the value of the (F-test) which is less than (P< 0.01), The maximuim mean result was shown by group III, while the minimum result was shown by group I. Conclusions: Within the limitations of this study, although both 3D-printing and CAD/CAM methods of framework fabrication revealed clinically acceptable adaptation, the conventional cast RPD groups revealed less overall porosity. https://edj.hmu.edu.krd/index.php/journal/article/view/186Conventional lost-wax3D PinterCAD/CAM techniquesPorosity
spellingShingle Fryad Mustafa Rasheed
Rizgar Mohammed Ameen Hasan
The effect of different fabrication techniques on porosity of cobalt-chromium cast removable partial denture farm works.
Erbil Dental Journal
Conventional lost-wax
3D Pinter
CAD/CAM techniques
Porosity
title The effect of different fabrication techniques on porosity of cobalt-chromium cast removable partial denture farm works.
title_full The effect of different fabrication techniques on porosity of cobalt-chromium cast removable partial denture farm works.
title_fullStr The effect of different fabrication techniques on porosity of cobalt-chromium cast removable partial denture farm works.
title_full_unstemmed The effect of different fabrication techniques on porosity of cobalt-chromium cast removable partial denture farm works.
title_short The effect of different fabrication techniques on porosity of cobalt-chromium cast removable partial denture farm works.
title_sort effect of different fabrication techniques on porosity of cobalt chromium cast removable partial denture farm works
topic Conventional lost-wax
3D Pinter
CAD/CAM techniques
Porosity
url https://edj.hmu.edu.krd/index.php/journal/article/view/186
work_keys_str_mv AT fryadmustafarasheed theeffectofdifferentfabricationtechniquesonporosityofcobaltchromiumcastremovablepartialdenturefarmworks
AT rizgarmohammedameenhasan theeffectofdifferentfabricationtechniquesonporosityofcobaltchromiumcastremovablepartialdenturefarmworks
AT fryadmustafarasheed effectofdifferentfabricationtechniquesonporosityofcobaltchromiumcastremovablepartialdenturefarmworks
AT rizgarmohammedameenhasan effectofdifferentfabricationtechniquesonporosityofcobaltchromiumcastremovablepartialdenturefarmworks